I've now discharged 32 cells!
3 were 'bad' with a capacity below 200mAh.
Some were in the 1500mAh range.
The majority came in between 1800mAh to 2300mAh.
Some were from before I calibrated properly and were cycled again. They all went up in capacity a similar amount.
I've also tested several post-calibration cells twice to check consistency. They all went up in capacity between 80-150mAh on the second charge/discharge cycle. I'm assuming this was the result of bringing them back from ~2.8v and that they are regaining some capacity by being cycled.
<EDIT> I cycled two of these consistency check cells one more time.
The first one reported 3mAh higher capacity. The second one reported 42mAh higher.
That is way more consistent than I expected. I'll take it.
</EDIT>
I've also moved the same cell between discharge slots and so far the numbers look good.