walker-arceWalker Arce 01/19/2020 at 00:320 Comments

Volumetric comparison of scans obtained at varied speeds (2, 4, 6, 8, 10, 20, 30, 40 and 50 RPM) at a fixed distance revealed consistency in the quality and relative accuracy of the produced meshes. In general, no measure differed from the mean volume (434.16 ± 19.61 cm3) by more than 6.13%, which occurred only at the highest speed of 50 RPM. This indicates that the apparatus is both repeatable and accurate in its model creation.

RPM

Volume

% Difference

2

456.46

5.135548066

4

441.32

1.648381178

6

452.27

4.170473478

8

424.22

-2.290228716

10

405.81

-6.530568373

20

431.83

-0.537432149

30

414.16

-4.607329039

40

420.62

-3.119409746

50

460.78

6.130565302

Discussions