Steps that will be taken:
1. Take raw reading of all pixels in 5sec intervals for 1 hour while pointing to uniform temp plate at room temperature. This will show how big error each pixel has and thermal drift of each pixel though time.
2. Create a diff matrix 208x156 with values showing difference between each pixels raw value and the correct value.
3. Repeat steps 1 and 2 while pointing to heated bed with temp set to 50*C and 100*C.
3. Find all pixels that do not response to temperature change and generate a badpixel map for further usage.
4. Implement a code that compensates each pixel drift with diff matrix.
5. Replace all badpixels with special averaging of neighbour pixels values.
6. Create realtime software
So, I just got my Seek Compact, pushed my vitals to the thread asking for versions, etc. Found the ThermoVision by JoeC thread, downloaded same, and after fighting with it to get it to connect to my camera, hopped on the 'net to try to solicit some support and read some more and ... the effin datacenter catches on fire and takes down Dave's forums until further notice. FML. lol