First test to measure voltage and current waveform
02/09/2017 at 21:25 • 0 commentsUsing components I already have, hopefully without the need to purchase anything else.
The first current transformer (CT) was from an Ega energy monitor 71A - 25mA.
No of coils = 71 / 0.025 = 2480
The second CT purchased from eBay a YHCD SCT013 100A 50mA cost £7.91
No of coils = 100 / 0.050 = 2000
Burden resistor calculation
CT1 = // PV - measured between inverter and consumer unit
CT2 = // measured at my side of supply grid's meter
Circuit is based in Robin Emerly's PV router mk2
Tests run using his code with scripts: rawSamples.ino phase Checker and calPhase